WEBVTT
Kind: captions
Language: en

00:00:29.279 --> 00:00:33.500
.
Hello, allwelcome back to the session, today

00:00:33.500 --> 00:00:38.130
we will be talking about assessment of thermal
environment.

00:00:38.130 --> 00:00:45.190
We are talking about the evaluation of work
place, so ergonomic workplace evaluation.

00:00:45.190 --> 00:00:52.760
So, when we are talking about ergonomic workplace
inevaluation environment physical environment

00:00:52.760 --> 00:01:01.550
is very very important component in terms
ofperformance, productivity,or the kind of

00:01:01.550 --> 00:01:04.259
design we have around ok.

00:01:04.259 --> 00:01:11.750
So, if we understand the some concepts of
thermal environment how we can measure them,

00:01:11.750 --> 00:01:17.970
how the impact is there of the thermal environment
on us.

00:01:17.970 --> 00:01:25.649
Andwhat are the varieties of you knowcomfort,
expressions orsensitivities are there, then

00:01:25.649 --> 00:01:33.160
it will be very easy when we are talking about
the physical environmentinergonomic workplace

00:01:33.160 --> 00:01:34.320
evaluation.

00:01:34.320 --> 00:01:43.979
So, today's topic ishow we can do the assessment
for thermal environment, so, let us first

00:01:43.979 --> 00:01:46.369
understand what it is.

00:01:46.369 --> 00:01:53.080
So, thermal environment hasmajor influence
as I mentioned earlier on the performance

00:01:53.080 --> 00:01:59.130
ok, so if you caneasily understand this one
from your own experience.

00:01:59.130 --> 00:02:07.479
So, if the environment is not conducive or
not comfortable in terms ofheat then we feel

00:02:07.479 --> 00:02:13.709
discomfort and discomfort definitely affects
your performance sense of well being right.

00:02:13.709 --> 00:02:20.540
When you do not feel good, sowhen we are talking
abouthealth; like, suppose we are working

00:02:20.540 --> 00:02:28.070
oras this whole topic is on the occupational
health like ergonomics workplace, so workplace

00:02:28.070 --> 00:02:30.540
dependswhen we are working.

00:02:30.540 --> 00:02:36.980
So, when we are working in a particular kind
of extreme environment definitely that has

00:02:36.980 --> 00:02:41.239
an effect on the physiology what we discussed
in earlierdays.

00:02:41.239 --> 00:02:48.620
So, on the physiology if it is affecting then
the whole physiological system maybe digestive

00:02:48.620 --> 00:02:54.040
system, maybe respiratory system, they will
have an effect, so it will affect the health

00:02:54.040 --> 00:03:01.790
. So, major factors that influence peoples
thermal comfort that is if the environment

00:03:01.790 --> 00:03:06.010
is too hot, or too cold then there will be
a problem.

00:03:06.010 --> 00:03:12.049
So, the ambient conditions such as thermal
environment, interior layout, building structure,

00:03:12.049 --> 00:03:16.290
it always has an effect on the total experience.

00:03:16.290 --> 00:03:22.750
There also these are the the first what we
talk that the ambient condition, environment,

00:03:22.750 --> 00:03:27.980
interior layout, these are the physical factors
present in the workplace.

00:03:27.980 --> 00:03:34.670
But, something which is personal like you
know your own physical fitness, your own psychological

00:03:34.670 --> 00:03:41.590
status of that current situation on that particular
situation that also has an impact or has an

00:03:41.590 --> 00:03:46.170
relation with the thermal environment or thermal
comfort basically.

00:03:46.170 --> 00:03:53.880
So, we did in certain limits the human body
can adopt the changes in thermal environment

00:03:53.880 --> 00:03:55.879
depending on the persons metabolic rate.

00:03:55.879 --> 00:04:00.030
So, what is metabolic rate that we will be
talking later.

00:04:00.030 --> 00:04:08.340
When we are talking about thermal environment,
like heat and how it is getting balanced we

00:04:08.340 --> 00:04:14.739
need to really understand what is the heat
balance we maintain in a particular workplace

00:04:14.739 --> 00:04:16.010
or in surrounding.

00:04:16.010 --> 00:04:23.530
So, it is very simple that S what we call
at this heat storage of the body is equal

00:04:23.530 --> 00:04:31.060
to M that is means metabolic heat production,
like heat generates within our body, so that

00:04:31.060 --> 00:04:34.000
is the source of energy right source of heat.

00:04:34.000 --> 00:04:42.520
So, from that different subtraction of sources
like W that is the external work, minus C

00:04:42.520 --> 00:04:51.320
that is the heat loss by convection, minus
R that is the heat loss by radiation, Esk

00:04:51.320 --> 00:04:55.220
that is the evaporation heat loss from your
skin.

00:04:55.220 --> 00:05:01.060
So, many times it happens when we are working
we discuss this on during our physiological

00:05:01.060 --> 00:05:07.419
fundament fundamentals or physiology that
some perspiration continuously happens from

00:05:07.419 --> 00:05:13.570
our skin that we do not understand and something
is the, so it absorption, so that also separate

00:05:13.570 --> 00:05:17.520
.
So, that is one then Cres convective heat

00:05:17.520 --> 00:05:25.180
loss from your respiration, Eres evaporation
heat loss from respiration, and K that the

00:05:25.180 --> 00:05:32.860
heat loss by conduction . So, this is the
basic heat balance mechanism or heat balance

00:05:32.860 --> 00:05:36.350
formula that our body follows.

00:05:36.350 --> 00:05:44.740
So, the that is very important when we understand
the thermal comfort and the available heat

00:05:44.740 --> 00:05:45.740
within surrounding.

00:05:45.740 --> 00:05:52.400
So, when we are talking about thermal environment
or thermal physical environment, thermal indices

00:05:52.400 --> 00:06:02.520
is a very importantnomenclature or very important
aspect what we always measure and compare

00:06:02.520 --> 00:06:03.520
ok.

00:06:03.520 --> 00:06:05.360
So, what these are?

00:06:05.360 --> 00:06:12.680
This is a very useful tool for describing,
designing, and assigning thermal environments

00:06:12.680 --> 00:06:19.300
in the thermal index right .
So, principle is that factors that influence

00:06:19.300 --> 00:06:26.810
human response to thermal environments are
integrated to provide a single index value.

00:06:26.810 --> 00:06:33.389
So, whatever the components are there within
the environment as per as thermal is concerned

00:06:33.389 --> 00:06:39.790
we are translating them into a single index
value which is very easy then to compare or

00:06:39.790 --> 00:06:45.770
to use further .
The aim is that the single value varies as

00:06:45.770 --> 00:06:53.099
human responses varies; like, if the indices
is on the higher side, or on the lower side

00:06:53.099 --> 00:07:00.840
my responses towards thermal environment will
also change accordingly and this can be used

00:07:00.840 --> 00:07:04.220
as to predict the effects.

00:07:04.220 --> 00:07:11.610
Because, suppose some index says that if the
index value is lower than this particular

00:07:11.610 --> 00:07:18.199
point, then we are a prediction is the human
being in normal condition we will feel comfort

00:07:18.199 --> 00:07:22.160
.
So, if we understand that index value or if

00:07:22.160 --> 00:07:28.250
we measure the index value we can predict
the person who is working in that particularlocation

00:07:28.250 --> 00:07:34.930
or particular work environment we will feel
comfort, and the performance or productivity

00:07:34.930 --> 00:07:37.289
will be as expected.

00:07:37.289 --> 00:07:46.470
If there is change or there is somedifference
in thatphenomena maybe we need to look intoor

00:07:46.470 --> 00:07:49.470
look back what is the problem.

00:07:49.470 --> 00:07:58.300
So, it really helps this indices really helps
to understand the hmthough those critical

00:07:58.300 --> 00:08:04.810
you know criteria or critical points whereergonomic
evaluation need to start .

00:08:04.810 --> 00:08:11.830
So, a thermal comfort index for example, would
provide a single number which is related to

00:08:11.830 --> 00:08:19.530
the thermal comfort that I was talking earlier
of that particular occupation of a particular

00:08:19.530 --> 00:08:20.530
environment right.

00:08:20.530 --> 00:08:27.380
So, suppose a person working in a maybe we
can take an example like fish processing industry

00:08:27.380 --> 00:08:34.500
right, so lot of coldthe temperaturearound
surrounding temperature is very cold.

00:08:34.500 --> 00:08:42.110
So, what if we understand the indexah particular
thermal index over there then we can find

00:08:42.110 --> 00:08:48.660
that how long the person is comfortable to
do their job in that particular index ok.

00:08:48.660 --> 00:08:55.819
So, based on that maybe we can decide on the
workers cycle or maybe we can decide on the

00:08:55.819 --> 00:09:01.210
what kind of clothing we should give, so that
comfort level can come back ok.

00:09:01.210 --> 00:09:08.380
So, these are the decision making point we
choosewhen we are talking about the thermal

00:09:08.380 --> 00:09:14.310
indices .
So, let metell the rational of these indices,

00:09:14.310 --> 00:09:21.140
so rational thermal indices are developed
with the help of heat transfer equation what

00:09:21.140 --> 00:09:26.579
wediscussed earlier that heat balance and
heat transport equation and in some cases

00:09:26.579 --> 00:09:31.600
mathematical representation of physiological
thermoregulation right.

00:09:31.600 --> 00:09:36.730
So, physiological thermoregulation we discussed
that how it happens?

00:09:36.730 --> 00:09:45.199
It happens through our hypothalamus and all
thishm physiological phenomena likeATP transfersto

00:09:45.199 --> 00:09:46.699
in translate to ADP.

00:09:46.699 --> 00:09:52.150
And then you know heat generates there has
metabolism happening through that heat generates

00:09:52.150 --> 00:09:57.220
all these calculations ok .
These are used to predict human responses

00:09:57.220 --> 00:09:59.110
in various thermal environment.

00:09:59.110 --> 00:10:08.490
Let us take an exampleindex to determine how
wet the skin is maybe the index we can call

00:10:08.490 --> 00:10:12.800
w, w is equal to E divided by E max.

00:10:12.800 --> 00:10:14.320
What is w?

00:10:14.320 --> 00:10:23.130
W is the index of skin wettedness right, how
wet my skin is, how we can calculate that?

00:10:23.130 --> 00:10:28.240
E divided by E max, E means actual evaporation
rate.

00:10:28.240 --> 00:10:36.520
So, what currently is happening divided by
E max means how maximum evaporation rate can

00:10:36.520 --> 00:10:44.660
be . So, based on that, so if it is the actual
one is tending to the maximum then I will

00:10:44.660 --> 00:10:51.230
understand my skin is going to dry if it is
not happening it is less then maybe there

00:10:51.230 --> 00:10:57.620
are some accumulation of humidity on my skin,
so I will feel little wettedness right.

00:10:57.620 --> 00:11:05.459
So, these are some indices that can help us
to understand the comfort as well as it will

00:11:05.459 --> 00:11:06.900
help us to understand.

00:11:06.900 --> 00:11:12.089
It will not give direct measurement, but it
will help us to get an idea how the performance

00:11:12.089 --> 00:11:19.370
or productivity is getting affected oris there
any scope of design intervention to improve

00:11:19.370 --> 00:11:20.880
the situation or not.

00:11:20.880 --> 00:11:28.060
So, when we are talking about empirical indices
these are developed based on the data collected

00:11:28.060 --> 00:11:34.140
from human participants exposed to a long
range of environmental conditions ok.

00:11:34.140 --> 00:11:41.549
So, it is not that all of us sudden we someone
can develop that it needs real long exposure

00:11:41.549 --> 00:11:48.780
and lot of other calculation some examples
are, windshield index, some are comfort index

00:11:48.780 --> 00:11:51.740
and there are many others we will be discussing
few of them.

00:11:51.740 --> 00:12:00.679
Now, when we are talking aboutthermal index
or thermal indices one very important index

00:12:00.679 --> 00:12:03.569
is WBGT index Wet Bulb Globe Temperature.

00:12:03.569 --> 00:12:05.890
So, what it is?

00:12:05.890 --> 00:12:09.299
It comes under the direct indices.

00:12:09.299 --> 00:12:11.990
So, what is direct indices?

00:12:11.990 --> 00:12:17.370
Direct indices are measurements taken on simple
instrument, it is very important criteria

00:12:17.370 --> 00:12:25.220
that is the simple instrument . So, we need
we may not havefacility to measure lot of

00:12:25.220 --> 00:12:31.569
critical components or critical variables,
but, if we have some simple instruments that

00:12:31.569 --> 00:12:32.910
we will name them.

00:12:32.910 --> 00:12:40.410
So, if we have that maybe we can have a good
idea about the thermal impact or thermal environmental

00:12:40.410 --> 00:12:45.600
impact on the human body , so one of them
isWBGT index.

00:12:45.600 --> 00:12:54.380
So, for themeasuring the WBGT index we only
needdry bulb,wet bulb, andglobe thermometer

00:12:54.380 --> 00:12:57.290
which is very easily commonly available.

00:12:57.290 --> 00:13:06.020
And every workplace we can use thesethree
instrument to identify or to measure the WBGT

00:13:06.020 --> 00:13:07.020
index.

00:13:07.020 --> 00:13:12.439
It has a specific formula I would request
you to look into the books and find out and

00:13:12.439 --> 00:13:16.050
measure your own WBGT index wherever you are
working.

00:13:16.050 --> 00:13:24.860
Or you can do some evaluation hm based on
your idea or your understanding your surrounding

00:13:24.860 --> 00:13:30.540
physical environment and find out the WBGT
index of that particular location.

00:13:30.540 --> 00:13:35.750
One more important component is effective
temperature, it is also very much useful and

00:13:35.750 --> 00:13:38.950
commonly use used indice index.

00:13:38.950 --> 00:13:47.360
So, what it is it says is often used as an
estimate of a bodies surface temperature ok.

00:13:47.360 --> 00:13:53.540
It try to measure the not measure it gives
an estimation of the surface temperature when

00:13:53.540 --> 00:13:57.189
bodies emissive curve is not known.

00:13:57.189 --> 00:13:59.270
So, what it does?

00:13:59.270 --> 00:14:07.860
It is defined as the temperature of a steel
and saturated atmosphere very importantassumption

00:14:07.860 --> 00:14:14.360
is the steel and saturated atmosphere which
would in the absence of radiation produced

00:14:14.360 --> 00:14:18.180
the same effect as the temperature in question.

00:14:18.180 --> 00:14:22.410
So, a particular temperature we can test it
in different situation .

00:14:22.410 --> 00:14:28.589
So, effective temperature cannot be measured
by a thermometer , it is an experimentally

00:14:28.589 --> 00:14:36.080
determined index of the various combination
of dry bulb temperature, humidity, radiant

00:14:36.080 --> 00:14:41.280
condition, and air movement that include the
same thermal sensation.

00:14:41.280 --> 00:14:49.030
So, it is not only measurement of some physical
environment, it includes the sensation as

00:14:49.030 --> 00:14:54.439
well that is where it is effective temperature
and it talks about the surface of the skin

00:14:54.439 --> 00:14:55.439
ok.

00:14:55.439 --> 00:15:02.570
So, very much important when we are talking
about thermal comfort,performance, productivity

00:15:02.570 --> 00:15:04.300
and all thoserelevant topic.

00:15:04.300 --> 00:15:13.660
So, effective temperature is very very usefulindex
in industry and we practice itto understand

00:15:13.660 --> 00:15:17.530
and measure when we are talking about thermal
comfort.

00:15:17.530 --> 00:15:24.669
So,as we are talking about indices or thermal
indices, let us talk about thermal comfort;

00:15:24.669 --> 00:15:33.630
because , physical environment, physical thermal
environment hasdirect impact on the sensation,

00:15:33.630 --> 00:15:40.450
so the sensation orourperceptionis only the
thermal comfort.

00:15:40.450 --> 00:15:47.870
So what it is thermal comfort is the condition
of mind that express satisfaction with the

00:15:47.870 --> 00:15:53.709
thermal environment and is assessed by subjective
evaluation ok.

00:15:53.709 --> 00:16:04.020
So, it is not a measurement it is a subjective
evaluation, so it is defined bydifferent standards

00:16:04.020 --> 00:16:07.430
specially ANSI or ASHRAE ok.

00:16:07.430 --> 00:16:14.760
So, maintaining this standard of thermal comfort
for occupants of building or other enclosure,

00:16:14.760 --> 00:16:22.549
so when we are in within us surrounding is
one of the important goals of HVAC it design

00:16:22.549 --> 00:16:23.549
engineers.

00:16:23.549 --> 00:16:25.020
So, what they does?

00:16:25.020 --> 00:16:32.880
They try to achieve that all the occupants
of that particular room or enclosure should

00:16:32.880 --> 00:16:39.949
feel comfort to understand that they need
to understand what the thermal comforts talks

00:16:39.949 --> 00:16:48.390
about . So, basically this thermal comfort
depends on the different indices that components

00:16:48.390 --> 00:16:54.939
like air velocity,air temperature, humidity
and all those things .

00:16:54.939 --> 00:17:01.919
Most people will feel comfortable at room
temperature which normally ranges from 20

00:17:01.919 --> 00:17:07.510
to 22 degree centigrade, but this may vary
greatly between individuals and depending

00:17:07.510 --> 00:17:14.120
on the factors such as activity level, clothing,
humidity etcetera ok.

00:17:14.120 --> 00:17:21.780
Take example if the air temperature or the
the effective temperature of the that particular

00:17:21.780 --> 00:17:28.120
not effectiveif the temperatureof that particular
room is some degree centigrade suppose 20

00:17:28.120 --> 00:17:29.120
degree.

00:17:29.120 --> 00:17:35.580
And someone who iswearing a very thin cloth
and someone is wearing you know woolen sweater

00:17:35.580 --> 00:17:41.470
or something, Definitely the comfort level
will change, comfort level will vary from

00:17:41.470 --> 00:17:49.700
one person to another person right . So, this
talks the this thermal sensation , or perceived

00:17:49.700 --> 00:17:55.760
comfort is very important to understand when
we are talkwhen we are designing the interior,

00:17:55.760 --> 00:18:01.140
why this is important of course, we we are
talking the same thing.

00:18:01.140 --> 00:18:10.610
So, we say that if 75 percent of all occupants
within the building are thermal are telling

00:18:10.610 --> 00:18:17.160
that it is thermally comfort then it becomes
very easy to say the environment is good . The

00:18:17.160 --> 00:18:25.160
thermal environment has been shown to have
up to a 10 percent effect on the workers productivity,

00:18:25.160 --> 00:18:32.580
we are not very sure or it is not very easy
to directly measure that what is the percentage

00:18:32.580 --> 00:18:33.630
of impact.

00:18:33.630 --> 00:18:40.740
But, still it has been identified that it
is almost 10 percent or it can go up to 10

00:18:40.740 --> 00:18:47.900
percent and of course, it depends on the energy
consumption .

00:18:47.900 --> 00:18:55.750
Satisfaction with the thermal enrollment is
very important as thermal conditions are potentially

00:18:55.750 --> 00:19:06.340
life threatening for humans, if the core temperature
reaches the condition of hypothermia or hyperthermia.

00:19:06.340 --> 00:19:09.010
So, what is hypothermia?

00:19:09.010 --> 00:19:17.210
Hypothermia says that when your core body
temperature goes down to 35 degree centigrade.

00:19:17.210 --> 00:19:25.510
Hypothermia when it crosses 37 or 38 degree
centigrade then there may be a case of different

00:19:25.510 --> 00:19:29.330
physiological malfunction may befatal case
ok.

00:19:29.330 --> 00:19:38.210
So, if you do not understand the thermal comfort
it becomes very difficultto um take decision

00:19:38.210 --> 00:19:45.020
in in case of hypothermia and hyperthermia
. So, buildings modify the conditions of the

00:19:45.020 --> 00:19:53.050
external environment and reduce the comfort
that our body needs to do in order to stay

00:19:53.050 --> 00:19:58.610
stable at a normal human body temperature,
that is the designers role .

00:19:58.610 --> 00:20:04.920
So, important for that the correct functioning
of our physiological processes, why we need

00:20:04.920 --> 00:20:11.980
that core body temperature on a constant position
? Because, it helps us to function that physiological

00:20:11.980 --> 00:20:17.130
functions run in smooth way right, so that
needs to be done.

00:20:17.130 --> 00:20:24.460
So, thermal comfort has also been known to
lead to stick building syndrome symptoms,

00:20:24.460 --> 00:20:32.890
it also a very important sick building syndromewe
call it very it is very commonphrase, but

00:20:32.890 --> 00:20:38.310
determining that is very very difficult . So,
the combination of high temperature and high

00:20:38.310 --> 00:20:44.630
relative humidity serves to reduce thermal
comfort and indoor air quality.

00:20:44.630 --> 00:20:51.900
So, when we are talking about thermal comfort
we understood the terminal indices, but definitively

00:20:51.900 --> 00:20:58.270
thermal comfort has is thecausal factor of
many other things right.

00:20:58.270 --> 00:21:06.710
So, we should know the what are the influencing
factors available which actually affect the

00:21:06.710 --> 00:21:07.710
thermal comfort.

00:21:07.710 --> 00:21:15.270
So, there are three major factors one is environmental
factor , personnel factor, and contributing

00:21:15.270 --> 00:21:20.200
factor .
Now, these divisions are made by the ANSI

00:21:20.200 --> 00:21:26.890
and ASHRAE standard, there are may be some
changes in the terminology by different other

00:21:26.890 --> 00:21:33.300
researchers . So, for the environmental factor
air temperature, air movement, humidity and

00:21:33.300 --> 00:21:39.051
radiation will be considering as per the ANSI
standard . Personnel factor; metabolic rate

00:21:39.051 --> 00:21:46.740
and clothing, contributing factors; food and
drink, acclimatization, bodies shape, subcutaneous

00:21:46.740 --> 00:21:54.350
fat, age, gender, and state of health , these
are being defined by the ANSI and ASHRAE.

00:21:54.350 --> 00:21:57.290
So, let us understand what these are?

00:21:57.290 --> 00:22:04.180
So, air temperature , air temperature is the
most important environmental factor measured

00:22:04.180 --> 00:22:06.350
by the dry bulb ok.

00:22:06.350 --> 00:22:11.930
So, when we are talking about air temperature
we will be talking about the measurement of

00:22:11.930 --> 00:22:19.020
the dry bulb . This will determine the convictive
heat dissipation together with any air movement,

00:22:19.020 --> 00:22:29.060
in the presence of air movement the surface
resistance of the body is much reduced that

00:22:29.060 --> 00:22:30.540
we need to understand.

00:22:30.540 --> 00:22:37.450
Because, if you have a clothing there then
perceptions or comfort will be different,

00:22:37.450 --> 00:22:42.010
then the next parameter or variable is air
movement.

00:22:42.010 --> 00:22:49.080
So, based on the air movement your perception
or your comfort level changes and how we measure

00:22:49.080 --> 00:22:50.080
it?

00:22:50.080 --> 00:22:56.390
We measure in terms of velocity, so meter
per second normally we can translate it according

00:22:56.390 --> 00:23:02.600
to our requirement as well . Now, comes under
humidity, what it is?

00:23:02.600 --> 00:23:09.100
It is absolutely depend on the how much water
content we have within the environment, so

00:23:09.100 --> 00:23:16.550
normally we calculate this one as the relative
humidity, then one more important factor is

00:23:16.550 --> 00:23:17.550
radiation.

00:23:17.550 --> 00:23:23.280
So, radiation exchange will depend on the
mean temperature of the surrounding surface

00:23:23.280 --> 00:23:28.600
referred to as the Mean Radiant Temperature
MR.

00:23:28.600 --> 00:23:35.181
So, this particular variable is an important
measurement when we are talking about the

00:23:35.181 --> 00:23:36.930
thermal environment.

00:23:36.930 --> 00:23:44.070
The MRT cannot be measured directly of course,
but it can be approximated by globe temperature

00:23:44.070 --> 00:23:49.290
measurement ok .
The globe temperature ismat what is the see

00:23:49.290 --> 00:23:55.900
dry bulb, wet bulb, and globe temperature
these three thermometers are very very important

00:23:55.900 --> 00:24:01.910
when we are talking about the thermal environment
. So, what the this globe thermometer is very

00:24:01.910 --> 00:24:10.870
important it is a black copper sphere and
usually of 150 millimeter diameter we thermometer

00:24:10.870 --> 00:24:14.740
which is located exactly at the center of
the globe.

00:24:14.740 --> 00:24:22.340
Now, when we are talking about other contributing
factor major is metabolic rate ok, that is

00:24:22.340 --> 00:24:29.360
the source of the heat within the body . So,
people have different metabolic rates that

00:24:29.360 --> 00:24:36.890
can fluctuate due to activity level ok very
important, because if you run definitely heat

00:24:36.890 --> 00:24:39.309
production within in your body will be different.

00:24:39.309 --> 00:24:45.930
But, if you you are in a sedentary job the
production rate will be different , so environmental

00:24:45.930 --> 00:24:46.930
condition also.

00:24:46.930 --> 00:24:52.040
So, if you are in a cold room that metabolic
rate will change.

00:24:52.040 --> 00:25:01.620
Metabolic rate is expressed in MET unit MET
ok which can be defined as one MET equal to

00:25:01.620 --> 00:25:04.990
58.2 watt per meter square.

00:25:04.990 --> 00:25:12.350
So, these are the calculation that you need
to do when you are specifically calculating

00:25:12.350 --> 00:25:19.440
thethermaldiscomfort, thermal comfort, and
presents of heat within the environment and

00:25:19.440 --> 00:25:25.000
how the human being is interacting or reacting
on that particular aspect.

00:25:25.000 --> 00:25:32.080
So, this is ASHRAE standard,some of the activities
is being already calculated and mentioned

00:25:32.080 --> 00:25:33.080
by them.

00:25:33.080 --> 00:25:39.490
So, you can refer this table directly or based
on the requirement you may can calculate as

00:25:39.490 --> 00:25:40.490
well.

00:25:40.490 --> 00:25:47.460
When we are talking about thermal comfort
we already spoke aboutwhat kind of heat we

00:25:47.460 --> 00:25:56.310
have within the environment . Now, thermal
comfort very verymuch dependent on the clothing

00:25:56.310 --> 00:25:58.320
pattern right.

00:25:58.320 --> 00:26:07.110
So,we say that it is an important on the dominant
factor that affect heat dissipation ok, the

00:26:07.110 --> 00:26:10.140
heat will go out from the body.

00:26:10.140 --> 00:26:12.810
So, how the insulation is?

00:26:12.810 --> 00:26:19.110
So, very very important and it is being always
presented this particular clothing factor

00:26:19.110 --> 00:26:22.140
as clo values clo, clo value.

00:26:22.140 --> 00:26:30.200
So, it has very every fabric has their own
co clo value based on that we can decide what

00:26:30.200 --> 00:26:37.050
kind of insulation we have within our body
. So, this corresponds to an insulating cover

00:26:37.050 --> 00:26:44.520
of the wholebody of transmitters of 6.45 watt
per meter square K.

00:26:44.520 --> 00:26:53.361
Amount of insulation that allows a person
at rest to maintain thermal equilibrium in

00:26:53.361 --> 00:27:02.310
an environment at 21 degree centigrade innormally
ventilated room we consider as one clo.

00:27:02.310 --> 00:27:11.440
There are a number of ways to determine clothing
insulation provided by cloths, but the most

00:27:11.440 --> 00:27:20.140
accurateaccurate according to ASHRAE fundamentals
are measurements on heated manikins and on

00:27:20.140 --> 00:27:26.510
the active subjects, so definitively we can
get these measurements done.

00:27:26.510 --> 00:27:34.300
So, let us understandsome of the measurement,
so what are the measurement device criteria

00:27:34.300 --> 00:27:40.310
the majoring instrumentation that is defined
by ASHRAE need to be used shall meet the requirements

00:27:40.310 --> 00:27:43.020
of the measurement range.

00:27:43.020 --> 00:27:50.730
So, what is the whole range can be possible
it should measure that and accuracy given

00:27:50.730 --> 00:28:00.500
in ASHRAE standards 7 points 705 or ASHRAE
standard 1136 or in ISO 7726, these are the

00:28:00.500 --> 00:28:05.260
standards you can follow and you can get the
measurement device criteria.

00:28:05.260 --> 00:28:11.620
So, when we are talking about measurement,
let us understand where we should measure

00:28:11.620 --> 00:28:14.320
it, so measurement location position.

00:28:14.320 --> 00:28:21.620
So, measurement shall be made in occupied
zone of the building at locations where the

00:28:21.620 --> 00:28:26.790
occupants are known to or are expected to
spend their time.

00:28:26.790 --> 00:28:37.270
It is not that that this whole billthe whole
roomis or occupied by 1 person and the long

00:28:37.270 --> 00:28:40.880
room out that other corner no one is there.

00:28:40.880 --> 00:28:42.940
So, where do you measure?

00:28:42.940 --> 00:28:50.180
You will be measure only the location where
the occupant is, if that is not being defined

00:28:50.180 --> 00:28:56.970
or you cannot find that then what you should
do you should make measure it at the center

00:28:56.970 --> 00:29:00.890
of the room or the center of that particular
zone.

00:29:00.890 --> 00:29:07.780
One meter inward from the center of each of
the rooms wall in the case of exterior walls

00:29:07.780 --> 00:29:13.650
with window the measurement location shall
be one meter inward from this center of the

00:29:13.650 --> 00:29:14.690
largest window.

00:29:14.690 --> 00:29:22.130
Because, these are the sources of difference
in the environmental heat right, wind a position

00:29:22.130 --> 00:29:33.260
can change the wind speed . Then window positionwe
will change the wind speed also it maygive

00:29:33.260 --> 00:29:38.140
some other external heat within the in a rule.

00:29:38.140 --> 00:29:43.750
So, these are the things we should maintain
when we are talking about the measurement

00:29:43.750 --> 00:29:47.840
location , at which level we should measures
like height.

00:29:47.840 --> 00:29:58.860
So, air temperature or air speed shall be
measured at the 0.1 0.6 or 1.1 meter levels

00:29:58.860 --> 00:30:04.560
for sedentary occupation if the person is
in seated condition.

00:30:04.560 --> 00:30:14.290
Same thing will vary if the person is standing,
so that will be 0.1 1.1 or 1.7 meter.

00:30:14.290 --> 00:30:23.090
So, operative temperature or PMV PPD shall
be measured or calculated at the 0.6 meter

00:30:23.090 --> 00:30:30.340
level for seated occupation occupants if it
is standing then 1.1 meter level.

00:30:30.340 --> 00:30:39.400
Radiant asymmetry always we need to measure
at the 0.6 meter if seated, if standing then

00:30:39.400 --> 00:30:44.620
1.1 meter humidity also we follow the same
position.

00:30:44.620 --> 00:30:53.110
Now, when we are talking about measurement
we talked about thermal comfort very important

00:30:53.110 --> 00:30:58.800
is how we should gather data as per thermal
comfort is concerned.

00:30:58.800 --> 00:31:02.809
So, definitely it is a subjective approach,
what it is?

00:31:02.809 --> 00:31:09.450
So, subjective approach is basically aimed
at finding out the judgment about the perception

00:31:09.450 --> 00:31:17.090
of the thermal environment in terms of acceptability,
or preference of colder, or warmer environments

00:31:17.090 --> 00:31:21.120
.
So, we have various stand one very standard

00:31:21.120 --> 00:31:29.840
usedscale that is the ASHRAE 7 pointthermal
sensation scale which I mentioned here . So,

00:31:29.840 --> 00:31:39.549
the neutral point we call it as 0 , once we
go on the site like on the left hand side

00:31:39.549 --> 00:31:46.130
it keeps on getting like cool sensation cold
sensation here it is heat sensation.

00:31:46.130 --> 00:31:54.520
So, very important frequently usedscale is
this ASHRAE 7 point7 point thermal sensation

00:31:54.520 --> 00:31:55.520
scale.

00:31:55.520 --> 00:32:03.530
Now,these I am not going to elaborate, but
if require you cango into detail and if you

00:32:03.530 --> 00:32:08.440
have any further question you can come back
we made answer your queries.

00:32:08.440 --> 00:32:16.799
So, PMV PPD index is very important aspectwe
call it as thermal comfort model and we see

00:32:16.799 --> 00:32:20.190
where these PMV is located.

00:32:20.190 --> 00:32:25.809
So, these 0.0 is very important how the PPD
percentage is increasing on this side and

00:32:25.809 --> 00:32:28.590
how it is increasing on the this side.

00:32:28.590 --> 00:32:34.940
So, this model I am not going to explainah
very in detail , but you can follow this one

00:32:34.940 --> 00:32:40.850
if you have query you can come back .
Now, when we are talking about PMV and PPD

00:32:40.850 --> 00:32:47.790
index, so this can you see this one this is
very important that this whole zone ok this

00:32:47.790 --> 00:32:52.600
whole zone we call it as comfort zone.

00:32:52.600 --> 00:32:57.300
So, psychometric, or temperature relative
humidity chart, so again it is a by ASHRAE

00:32:57.300 --> 00:33:00.420
555or ASHRAE 5 5.

00:33:00.420 --> 00:33:10.140
So, what it says that if your comfort level
lies within this zone you are say, if it is

00:33:10.140 --> 00:33:14.820
outside then ityou are not in the comfort
zone.

00:33:14.820 --> 00:33:23.280
Now, concern is this particular phenomena
this whole particular phenomena is not globally

00:33:23.280 --> 00:33:24.330
true right.

00:33:24.330 --> 00:33:31.480
So, thethe phenomena is true sorry phenomena
is true, but this temperature ranges these

00:33:31.480 --> 00:33:38.950
temperature range is these these these these
ranges are not true always for every context.

00:33:38.950 --> 00:33:46.090
Based on the context these temper this zone
changes and it may go on this side it may

00:33:46.090 --> 00:33:51.990
go on this side .
So, based on your understanding, your requirement

00:33:51.990 --> 00:33:59.590
you need to establish this particular zone
and you have to find out where yourcomfortable

00:33:59.590 --> 00:34:01.440
zone is.

00:34:01.440 --> 00:34:09.520
Because,comfortability again orcomfortness
again depends on the adaptation capacity or

00:34:09.520 --> 00:34:13.490
habitual activities right, so those are important
aspect.

00:34:13.490 --> 00:34:21.389
Now, very important hm discussion is local
thermal discomfort what it is, according to

00:34:21.389 --> 00:34:30.270
ASHRAE 55 2010 standard there are four main
causes of thermal discomfort to be considered.

00:34:30.270 --> 00:34:38.720
A section of of the standards specifies that
requirements for these factors that applied

00:34:38.720 --> 00:34:47.280
to the lightly clothed person engaged in near
sedentary physical activity ok .

00:34:47.280 --> 00:34:55.990
So, this is because people with higher metabolic
rate and a more clothing insulation are less

00:34:55.990 --> 00:34:57.610
thermally sensitive.

00:34:57.610 --> 00:35:05.530
Because , they are not in touch with the direct
environment and consequently have less risk

00:35:05.530 --> 00:35:13.110
of thermal discomfort ok , but based on the
context this phenomena definitely will change.

00:35:13.110 --> 00:35:19.070
Now, let me talk little bit about these standards,
we have varieties of standards.

00:35:19.070 --> 00:35:27.440
So, ISO ASHRAE 55, it says about the thermal
environmental conditions for human occupancy.

00:35:27.440 --> 00:35:34.220
ISO 7993, it talks about hot environment,
analytical determination and inter pretation

00:35:34.220 --> 00:35:44.150
of thermal stress using calculation of required
sweat rate ok, so these aremainly on the thermal

00:35:44.150 --> 00:35:47.730
comfort
We have something for the indoor thermal environment

00:35:47.730 --> 00:35:56.340
that is ISO 77 26, it talks about the ergonomics
of the thermal environment, instruments for

00:35:56.340 --> 00:36:03.750
measuring physical quantities and ASHRAE 55
that also talks about thermal environmental

00:36:03.750 --> 00:36:07.380
condition for human occupancy which is same.

00:36:07.380 --> 00:36:12.270
Now, there are some standards which deals
with the design of the indoor environment

00:36:12.270 --> 00:36:19.020
like ASHRAE 62, ventilation for acceptable
indoor yard quality.

00:36:19.020 --> 00:36:26.240
CR 1752 ventilation for buildings design,
criteria for the indoor environment . Standards

00:36:26.240 --> 00:36:34.630
for determination of the personal factor like
ISO 8996 that talks about the the the chapter

00:36:34.630 --> 00:36:41.400
name is ergonomics determination of metabolic
heat production , and ISO 9920 that is the

00:36:41.400 --> 00:36:48.300
estimation of the thermal insulation and evaporative
resistance of the clothing and symbol.

00:36:48.300 --> 00:36:54.440
When we are talking about all these aspects
like thermal discomfort, thermal comfort,

00:36:54.440 --> 00:37:01.970
thermal temperature, indices measurement and
all those thing, so practical assessment of

00:37:01.970 --> 00:37:04.320
thermal environment is very very important.

00:37:04.320 --> 00:37:10.359
So, this particular principle provided this
particular principle whatever we are following

00:37:10.359 --> 00:37:17.760
for the practical assessment can be used to
develop a practical methodology to assess

00:37:17.760 --> 00:37:24.050
any thermal conditions based on the human
responses what you can do yourself.

00:37:24.050 --> 00:37:31.680
However, if you see through the literature
there is no globally acceptable like which

00:37:31.680 --> 00:37:38.000
is applicable for all contexts that kind of
methodology is not being established till

00:37:38.000 --> 00:37:39.000
now.

00:37:39.000 --> 00:37:44.470
So, based on your context you need to really
develop your own methodology and you have

00:37:44.470 --> 00:37:46.180
to work on.

00:37:46.180 --> 00:37:54.170
When we are talking aboutmeasurement or assessment
we can have three variety hot, moderate and

00:37:54.170 --> 00:37:59.650
cold, so for hot environment measurementor
not measurement assessment.

00:37:59.650 --> 00:38:06.810
So, evaluation ofcomfort and stress we can
go for WBGT index which is being mentioned

00:38:06.810 --> 00:38:17.950
in ISO 7243 and WBGT required sweat rate this
is again some modification in 7933 that is

00:38:17.950 --> 00:38:22.220
also ISO physiological strain evaluation.

00:38:22.220 --> 00:38:30.920
What it is mainly the core, and skin temperature,
heart rate must lost sweating and respiration,

00:38:30.920 --> 00:38:36.570
psychological strain evaluation, subjective
assessment method, so and the surface temperature

00:38:36.570 --> 00:38:40.440
which is being mentioned in iso 13732 1.

00:38:40.440 --> 00:38:48.390
So, these you canhaveunderstanding when we
are talking about the hot environment assessment.

00:38:48.390 --> 00:38:55.560
Now, if we are talking aboutmoderate environment
assessment predicted mean vote and predicted

00:38:55.560 --> 00:38:57.180
percentage dissatisfied.

00:38:57.180 --> 00:39:08.390
So, which we already spoke about thatmodel
that is beingpresented very in detail ISO

00:39:08.390 --> 00:39:14.890
7730 . Physiological strain and evaluation
again the same core, and skin temperature,

00:39:14.890 --> 00:39:21.220
heart rate, mass lost sweating, and respiration,
subjective assessment method, and surface

00:39:21.220 --> 00:39:22.220
temperature.

00:39:22.220 --> 00:39:29.100
And cold environment same windshield index
what I mentioned in the very first light,

00:39:29.100 --> 00:39:35.790
then physiological same again core, skin temperature,
heart rate, mass lost of sweating, respiration

00:39:35.790 --> 00:39:36.790
etcetera.

00:39:36.790 --> 00:39:42.950
And subjective assessment method, and surface
temperature which is depicted in 13732 part

00:39:42.950 --> 00:39:50.780
3, so the previous one is part 2 the first
one is part 0 and the third one is part 3,

00:39:50.780 --> 00:39:55.730
so this way you can access .
So, see all these the cold cores we will be

00:39:55.730 --> 00:40:00.240
talking about different application and the
assessment criteria.

00:40:00.240 --> 00:40:06.250
So, detailing is not possible, but of course,
when you are talking about all these assessment

00:40:06.250 --> 00:40:11.810
measurement, you can practice yourself, you
can generate your own methodology, you can

00:40:11.810 --> 00:40:15.610
enquire back with me for better clarification
.

00:40:15.610 --> 00:40:24.109
So, this is one of thebook what Iask you to
refer, if you want to know more also there

00:40:24.109 --> 00:40:31.840
are varieties of literature available which
will help youto understand and explore more

00:40:31.840 --> 00:40:36.990
about the impact of thermal environment on
the performance and productivity.

00:40:36.990 --> 00:40:46.570
And how that theno it it is relevant orit
is related to the ergonomic workplace evaluation

00:40:46.570 --> 00:40:56.641
and if how we can take those key points todesign
or design modification or the thermal environment

00:40:56.641 --> 00:40:58.160
changes ok.

00:40:58.160 --> 00:41:07.640
So,hm what will be the instruction for you
is whatever we discussed today please take

00:41:07.640 --> 00:41:16.300
each point practice it at home, find out what
that the varieties or possibilities are there

00:41:16.300 --> 00:41:17.380
in your research area.

00:41:17.380 --> 00:41:20.830
And if you have any query come back to me
for better clarification.

00:41:20.830 --> 00:41:21.319
Thank you .